Counter Flashing

Metal counter flashing tucked into the mortar joints of a brick chimney above an asphalt shingle roof

A ceiling stain near the chimney is one of the most common roof leaks in America, and the shingles are almost never the cause. The cause is usually a thin strip of metal most homeowners have never heard of: counter flashing. It is the top layer of the two part flashing system that seals every place a roof meets a vertical wall, and when its seal fails, water runs straight behind the flashing and into the house. Roofing inspectors rank failed flashing as the number one source of avoidable interior leaks, and the counter flashing seal at the chimney is the single most common failure they find.

The frustrating part is how small the problem is. A bead of sealant drying out in a saw cut groove can start a leak that rots decking, stains ceilings, and feeds mold in the attic for years before anyone notices. This guide explains what counter flashing is, how it works with the step flashing below it, how it is installed, what it costs to repair or replace, and how to spot trouble from the ground before the damage spreads. It is part of the same weather defense as the roof underlayment under your shingles, and it deserves the same attention.

What Counter Flashing Is

Counter flashing is the upper layer of metal flashing that covers and protects the base flashing at a roof to wall intersection, most often at a chimney, a parapet wall, or a dormer sidewall. It is embedded into the vertical surface, cut into a mortar joint on brick or tucked behind siding on a wood framed wall, and it hangs down over the base flashing below it like a curtain. Its sole job is to keep water from getting behind the base flashing.

Base flashing, usually step flashing or a continuous apron, directs water down the roof. Counter flashing covers the top edge of that base flashing so water running down the wall cannot blow behind it. Without counter flashing, wind driven rain pushes water up and over the top edge of the base flashing, into the wall cavity, and down through the ceiling below. The base flashing handles gravity fed water. The counter flashing handles wind driven water. Both are required for a waterproof roof to wall junction.

Counter flashing is also called cap flashing, because it caps the top of the flashing assembly. It is usually made from galvanized steel, aluminum, copper, or stainless steel, and it is formed on site or in a sheet metal shop to fit the exact chimney or wall it protects.

Why the Two Part System Exists

The two part design solves a movement problem. Base flashing is nailed to the roof deck and woven into the shingles, so it moves with the roof as temperatures change. Counter flashing is attached to the vertical structure, a masonry chimney or a framed wall, which moves independently of the roof. If the two layers were nailed together as one piece, the different movement would tear the seal apart within a few seasons.

By keeping the layers separate, the system lets the roof and the wall shift relative to each other while the overlap stays watertight. The counter flashing hangs freely over the base flashing, overlapping it by at least 2 inches, and gravity plus the overlap do the work. No sealant at that joint is needed, because water cannot run uphill past a 2 inch overlap. The only sealed joint in the whole assembly is the one at the top, where the counter flashing enters the wall, and that is exactly where most failures start.

Where Counter Flashing Is Used on a Roof

Counter flashing is installed at every location where a vertical surface meets the roof and the top edge of the base flashing would otherwise be exposed to wind driven rain. The four most common locations are:

Chimneys. The single most common counter flashing location, and the one where it fails most often. The counter flashing around a chimney is cut into a groove in the mortar joints, called a reglet, and sealed with mortar, silicone, or lead wedges. The base step flashing is installed on the roof side first, and the counter flashing is then embedded into the brick above it, hanging down over the step flashing by at least 2 inches.

Parapet walls. On a flat roof, the membrane runs up the inside face of the parapet wall and is terminated with a metal coping cap at the top. The coping cap is counter flashing. It covers the top edge of the membrane and keeps water from getting behind the membrane at the wall to roof junction. Our guide to what is TPO roofing covers the flat roof systems where this detail matters most.

Dormer sidewalls and wall to roof intersections. On a sided wall, the siding itself acts as the counter flashing. The vertical leg of the step flashing tucks behind the house wrap and the bottom edge of the siding. The siding hangs down over the top of the step flashing and serves the same water shielding function as metal counter flashing on a chimney.

Skylights. Factory skylight kits include their own step and counter flashing systems, and the counter flashing pieces lap over the step flashing around the curb. If they are installed out of sequence, the skylight leaks even with brand new shingles, so the order of the layers matters as much as the metal itself.

Counter Flashing vs Step Flashing vs Base Flashing vs Apron Flashing

The terms get mixed up because all four pieces work together at the same roof junction and are often made of the same metal. The difference is where each piece sits and what it protects against.

Flashing TypePositionProtects AgainstAttached To
Step flashing, also called base flashingUnder shingles, against the wall, one piece per shingle courseGravity driven water running down the wallRoof deck, nailed under shingles
Counter flashingOver step flashing, embedded in the wallWind driven rain blowing behind the step flashingWall, set in a mortar joint or behind siding
Apron flashingBottom of the chimney, over shinglesWater flowing down the roof and hitting the chimney faceRoof deck and chimney face
Cricket, also called a saddleUphill side of a wide chimneyWater pooling against the back of the chimneyRoof deck behind the chimney

The field test to tell them apart is simple. If you can lift the bottom edge of the metal and see the shingle or roofing material underneath, it is counter flashing. If the metal is under the shingles and you cannot lift it without removing roofing, it is base flashing. Counter flashing hangs over. Base flashing is buried under.

A complete chimney flashing system has four pieces working together: apron flashing on the downhill side, step flashing woven up both sides, a cricket on the uphill side when the chimney is 30 inches wide or wider, and counter flashing over the top of the step and apron. Building code requires a cricket on chimneys that wide, and it is one of the most commonly missing pieces on homes built before 2000. If your chimney is wide and has no cricket, water piles up against its back in every rain, and no amount of sealant at the counter flashing will fix that.

How Counter Flashing Is Installed: Reglet vs Surface Mount

Counter flashing is installed in one of two ways: cut into the wall, called the reglet method, or attached to the surface of the wall, called the surface mount method. The reglet method is the only one that lasts.

The Reglet Method

A reglet is a horizontal groove cut into a mortar joint of a brick or stone chimney or wall, usually 3/4 to 1 inch deep. The groove follows the mortar joint because mortar is softer and easier to cut than brick. The top edge of the counter flashing is bent into an L shape and inserted into the groove, then sealed with mortar, a lead wedge, or a bead of high quality silicone. The reglet mechanically locks the counter flashing into the wall. It cannot pull out without breaking the sealant or the mortar wedge.

The work follows a fixed sequence. First the mason or roofer marks the reglet line one or two mortar joints above the roofline, high enough that the flashing hangs down over the step flashing by at least 2 inches. Then the groove is cut with an angle grinder fitted with a diamond blade, working along the mortar joint on all four sides of the chimney. The groove is cleaned out with a brush so the sealant bonds to sound mortar, not dust. The counter flashing pieces are bent to fit, the top edge is pushed into the groove, and the groove is filled with mortar or sealant. On the sides of the chimney, the counter flashing is stepped to follow the slope of the roof, with each piece overlapping the one below it like shingles.

A reglet mounted counter flashing lasts 30 to 50 years if the mortar or sealant is maintained every 10 to 15 years. Done correctly, counter flashing routinely outlasts two cycles of new roof installation, which is why roofers reuse the reglet and replace only the metal when a roof is torn off. Manufacturers such as GAF and Owens Corning publish flashing details for their shingle systems, and those details show the same reglet and overlap rules used here.

The Surface Mount Method

Surface mounted counter flashing is screwed or nailed to the face of the chimney or wall and sealed with a bead of caulk along the top edge. It relies entirely on the sealant to keep water from getting behind it. That sealant degrades under UV exposure and thermal cycling, cracks open, and admits water. The flashing itself is still intact, but the sealant joint is not.

A surface mounted counter flashing lasts 5 to 10 years before the sealant fails and needs recaulking. It is a budget repair method, not a permanent installation. The cost difference between the two methods is roughly $300 to $600 in labor, the mason time to cut the reglet groove. Paying that premium once during a roof replacement or a chimney rebuild is cheaper than recaulking the surface mounted flashing every 8 years for the next 40 years. If you see face sealed caulk smeared over a wall with no metal tucked into a joint, you do not have true counter flashing. That is a short lived fix, not a solution.

Counter Flashing Materials Compared

The metal you choose decides how long the flashing lasts and how much it costs. All four common metals work, but they fail in different ways and at very different ages.

MaterialTypical CostExpected LifeBest For
Galvanized steelLowest20 to 30 yearsBudget jobs, dry climates
AluminumLow to moderate25 to 40 yearsMost shingle roofs, easy to bend on site
CopperHighest50 years or moreChimneys, slate and tile roofs, homes where the flashing should outlast the roof
Stainless steelHigh50 years or moreCoastal areas, chimneys with heat and masonry abrasion

Copper and stainless steel are favored around chimneys because they handle heat, UV, and the abrasive nature of masonry without corroding. Galvanized steel develops pinholes at the bend after 20 to 30 years, because water collects at the bend, pollutants accumulate, and the metal thins over decades until a pinhole opens. Copper and stainless steel resist that failure entirely.

One rule matters whichever metal you pick: never mix metals that corrode each other. Aluminum flashing against copper, or steel fasteners in copper flashing, sets up galvanic corrosion that eats the weaker metal. Match the flashing metal to the fasteners, the step flashing, and the roofing material, and ask the contractor to name the metals in the written scope before work starts.

Why Counter Flashing Fails

Counter flashing fails in a handful of predictable ways, and all of them produce the same symptom: a ceiling stain near a chimney or a wall on the top floor.

The reglet sealant or mortar deteriorates. Mortar in a chimney reglet cracks from thermal cycling. Silicone pulls away from the brick over 10 to 15 years. Water enters the groove, runs behind the counter flashing, and drips down onto the step flashing below. The step flashing is intact and would shed the water if the water stayed on top of it, but the water is now behind it, running down the wall cavity. Inspectors find this failure most often at 8 to 12 years after installation, and it is the number one source of chimney leaks they document.

The counter flashing lifts out of the reglet. Wind vibration, building settlement, or freeze and thaw cycles in the mortar joint can physically loosen the metal from the groove. The counter flashing pulls away from the wall by a quarter inch, enough for wind driven rain to blow behind it. The flashing looks fine from the ground, but it is no longer performing its function.

The counter flashing corrodes at the bend. The bend where the metal turns from the vertical wall leg to the drip edge that hangs over the base flashing is a stress point. Water collects at the bend, pollutants accumulate, and the metal thins over decades until a pinhole develops. Galvanized steel is the usual victim. Copper and stainless steel do not have this problem.

The counter flashing is missing entirely. On older homes, or after a sloppy reroof, the chimney may have step flashing with no counter flashing over it at all. The top edge of the step flashing sits exposed to wind driven rain, and the chimney leaks in every storm with wind behind it. A chimney with no visible metal band at the roofline has this problem.

Caulk was used instead of metal. Many chimneys have a glob of caulk where there should be counter flashing. Caulk fails in 3 to 5 years, guaranteed. The fix is to pull the caulk, cut a proper slot in the mortar, and install metal counter flashing.

The mortar joint itself fails. The masonry can pull back and release the counter flashing even when the metal is sound. The repair is to retuck the mortar joint and reset the counter flashing, which is a mason job, not a caulk job.

How to Inspect Counter Flashing From the Ground

You do not need a ladder to catch most counter flashing problems. A 30 minute visual inspection with binoculars and a phone camera, done twice a year and after any major storm, finds the failures before they become interior damage.

Walk the perimeter of the house and look up at the chimney sides for vertical rust streaks running down the brick. Rust streaks are the first visible sign that the reglet sealant has failed and water is getting behind the metal. Look for a metal band cut into the brick at the roofline, hanging down over the shingles or the step flashing below it. If you cannot see a metal line at the base of your chimney, the counter flashing is either missing or buried under sealant, and both are problems.

Check for gaps where the metal meets the brick, for sealant that has cracked or pulled away from the wall, and for flashing that has lifted or shifted out of line. Look at the ceiling inside the house near the chimney after heavy rain, and check the attic for damp insulation or dark streaks on the roof deck near the chimney. Water often travels along rafters and shows up far from the entry point, so a stain a few feet from the chimney can still trace back to the counter flashing.

Photograph anything that looks wrong from several angles, close up with zoom and a wider shot showing the location on the roof. Those photos are what a roofer or an inspector needs to scope the repair, and they are the same documentation a manufacturer or an insurer asks for when a warranty or a claim is involved. The National Roofing Contractors Association publishes flashing details that show how the cap, the step flashing, and the roof covering are meant to work as one system, and a good inspector checks each piece against those details.

Counter Flashing Repair and Replacement Costs in 2026

Costs vary by chimney size, roof access, and whether a reglet needs to be recut, but the ranges below come from published contractor pricing and cover most homes.

JobTypical Cost
Reseal the reglet, scrape old sealant and apply new$200 to $500
Recaulk surface mounted counter flashing$150 to $400
Replace counter flashing on a chimney, reglet recut included$600 to $1,800
Full chimney reflash, step and counter flashing plus apron$800 to $2,200
Add a cricket to a wide chimney$400 to $900
Retuck mortar joints before resetting the flashing$200 to $600
Replace rotted decking found under the chimney flashingMaterial cost on top of the reflash

Most flashing failures are repairable without a full reroof. A reseal of the reglet is a maintenance job, not a replacement, and it buys another 10 to 15 years when the metal is still sound. A full reflash is the right call when the step flashing is also damaged, when the flashing was never installed properly, or when rotted decking is found once the shingles are lifted. Get the scope in writing, with the reglet cut, the metal type, and the cricket called out as separate line items, because one contractor may include all three and another may propose surface caulking and paint for the same price. For the full cost picture on the roof around the chimney, see our guide to average roof replacement cost.

Counter Flashing on Metal Roofs

Metal roofs deserve a special note, because none of the general flashing guides cover them well and the details are different. A metal roof moves more with temperature than a shingle roof does, so the counter flashing needs a longer overlap and a slip joint that lets the panels expand without pulling the flashing out of the reglet. The chimney flashing on a metal roof also has more complex geometry, because the flashing must seal against raised seams or ribs rather than a flat shingle surface, and a leak there is harder to trace than on shingles.

On a standing seam roof, the counter flashing is usually formed with a wider hem and a deeper reglet, and the step flashing is replaced by a continuous curb flashing that is clamped to the seams. On a corrugated or exposed fastener metal roof, the flashing must follow the profile of the panels, and the sealant at each rib is a maintenance item. If your metal roof leaks near a chimney, the cap is only half the fix. The flashing and the seal at the chimney base need checking too, and that is a job for a roofer who works with metal every day. Our guide to the parts of a metal roof shows where the chimney flashing sits in the whole system, and our metal roofing service includes the chimney flashing details that a cap alone cannot fix.

Can You Replace Counter Flashing Yourself

A homeowner can handle the inspection and the recaulking. Resealing a reglet with fresh silicone is a reasonable do it yourself job if you are comfortable on a roof and the metal is still seated in the groove. Scrape out the old sealant, clean the groove with a wire brush, and apply a continuous bead of exterior grade silicone or polyurethane sealant made for masonry.

Cutting a new reglet and fabricating counter flashing is a different job. It needs an angle grinder with a diamond blade, a sheet metal brake to bend the flashing cleanly, and the judgment to cut along a mortar joint without cracking brick. A mistake here cracks the chimney or leaves a groove too shallow to hold the metal, and the leak comes back worse than before. A full reflash also means stripping shingles back two feet on all four sides of the chimney, inspecting the decking for rot, installing new ice and water membrane, and reshingling around the chimney in the right sequence.

Hire a professional when the reglet needs cutting, when the step flashing underneath is damaged, when the chimney is more than two stories tall or the roof is too steep to work on safely, or when the crown is cracked and needs repair before any flashing will seal. Our roof repair service can trace a chimney leak to its source and tell you whether the counter flashing, the step flashing, or both are at fault, and our residential roofing service covers the flashing, the cap, and the roof as one system so nothing gets missed between trades.

Maintenance: How Long Counter Flashing Lasts

Counter flashing is a fit and forget detail only if the seal at the reglet is maintained. Put it on the same annual schedule as the rest of the roof.

MaterialExpected LifeSeal Maintenance
Galvanized steel20 to 30 yearsReseal the reglet every 10 to 15 years
Aluminum25 to 40 yearsReseal the reglet every 10 to 15 years
Copper50 years or moreReseal the reglet every 10 to 15 years
Stainless steel50 years or moreReseal the reglet every 10 to 15 years

Inspect the flashing at the start of every heating season, ideally from the ground with binoculars first, then up close if anything looks wrong. Check the mesh of any chimney cap at the same time, since a cap and its flashing are inspected together in our guide to attaching a chimney cap. Check the sealant for cracks, check that the flashing is still tight in the reglet, and check the edge detail where the roof meets the wall in our guide to what is a drip edge on roof. A reglet reseal costs $200 to $500 and takes under an hour. A year of hidden leaking behind failed flashing can cost thousands in decking, insulation, and drywall. That is the whole case for counter flashing maintenance in one comparison.

Frequently Asked Questions

What is counter flashing on a roof? Counter flashing is the top layer of metal flashing that covers the base flashing at a roof to wall intersection, usually at a chimney. It is embedded into the wall, cut into a mortar joint on brick or tucked behind siding, and it hangs down over the base flashing to keep wind driven rain from blowing behind it.

What is the difference between counter flashing and step flashing? Step flashing is the base layer, nailed to the roof deck and woven under the shingles, one piece per shingle course. Counter flashing is the top layer, attached to the wall and hanging over the step flashing. Step flashing handles gravity fed water. Counter flashing handles wind driven water. Both are required.

How much does it cost to replace counter flashing? Replacing counter flashing on a chimney costs $600 to $1,800, including removing the old flashing, recutting the reglet if needed, fabricating new metal, and sealing the groove. Resealing an existing reglet costs $200 to $500, and recaulking surface mounted flashing costs $150 to $400.

How long does counter flashing last? A reglet mounted counter flashing lasts 30 to 50 years if the sealant or mortar in the reglet is maintained every 10 to 15 years. Copper and stainless steel last 50 years or more. Surface mounted counter flashing lasts only 5 to 10 years before the sealant fails.

Should counter flashing be visible from the ground? Yes. Counter flashing on a chimney should be visible as a metal band cut into the brick at the roofline, hanging down over the shingles or the step flashing below it. If you cannot see a metal line at the base of your chimney, the counter flashing is either missing or buried under sealant, and both are problems.

Can I paint counter flashing to match the chimney or wall? You can paint metal counter flashing with an exterior grade metal primer and paint, but the paint will peel and need repainting every 3 to 5 years. Galvanized steel and aluminum accept paint well. Copper and stainless steel do not, because paint does not adhere properly to their surfaces without an acid etch primer. Copper is usually left unpainted to develop its natural patina.

What is a reglet in roofing? A reglet is a horizontal groove cut into a mortar joint of a brick or stone wall, usually 3/4 to 1 inch deep. The top edge of the counter flashing is bent into an L shape and inserted into the reglet, then sealed with mortar or silicone. The reglet mechanically locks the flashing into the wall so it cannot pull out.

Does counter flashing need to be replaced when I get a new roof? Not always. A reglet mounted counter flashing often outlasts two roof installations, so a good roofer reuses the reglet and replaces only the metal if it is worn. What must be replaced with the roof is the step flashing underneath, which is woven into the old shingles. Reusing old step flashing on a new roof is one of the most common shortcuts, and it leaks.

Planning roof work around your chimney? Start with our guide to roof underlayment, check the edge detail in what is a drip edge on roof, or see the full system in parts of a metal roof. For a free inspection and an itemized quote on counter flashing, chimney flashing, or a full roof, contact our team.